VIKING DISCOVERS NEW VANADIUM ZONE 1.5KM FROM FOLD NOSE MRE
Released
Released
Announcement PDF
ASX ANNOUNCEMENT
12 September 2023
VIKING INTERCEPTS 14M AT 0.63% V2O5 >1.5KM FROM
FOLD NOSE RESOURCE
•
Drilling at the Fold Nose to Kinks South exploration target tested for Vanadiferous
Titanomagnetite (VTM) mineralisation >1.5km north of the Fold Nose Mineral
Resource Estimate (MRE).
•
Drilling has confirmed the discovery of further VTM mineralisation with:
• VCRC0045: 7m at 0.60% V2O5 (>0.5%) from 63m &
14m at 0.63% V2O5 (>0.8%) from 122m
• VCRC0044: 12m at 0.68% V2O5 (>0.5%) from 60m
•
All results now reported from the 45 holes drilled (including 1 re-entry) as part of
the ~7,500m programme completed by Viking.
•
Vikings drilling programme has proven to be highly effective, with substantial VTM
intercepts returned at all targets tested.
•
Mineral Resource Estimate (MRE) to be completed in the December quarter with
updates to the Fold Nose and Kinks Resources (79Mt at 0.64% V2O5) and the
inclusion of the newly discovered Kinks South area expected to substantially
improve the quality of the total MRE.
Viking Mines Ltd (ASX: VKA) (“Viking” or “the Company”) is pleased to provide an update
on final assay results received from drilling completed at the Canegrass Battery Minerals
Project (“the Project” or “Canegrass”), located in the Murchison region of Western Australia.
The Company drilled eight target areas focussed on extending and growing the already
substantial Inferred Mineral Resource Estimate (MRE) of 79Mt at 0.64% V2O51 estimated at
the Fold Nose and Kinks deposits.
Drilling at the Fold Nose to Kinks South target area has returned newly discovered zones of
vanadium mineralisation (reported as V2O5) in an area never before drilled.
These results confirm the hypothesis that VTM mineralisation continues between the MRE’s
at Fold Nose and Kinks South and demonstrates the opportunity to grow the Resource base
with further drilling.
Viking Mines’ Managing Director & CEO, Julian Woodcock, said:
“With these final results from the ~7,500m drilling programme, I am very pleased to see that
we have discovered more Vanadium mineralisation (in VTM) >1.5km from the Fold Nose MRE.
“This first pass wide spaced drilling in this previously undrilled area between the MRE’s at Fold
Nose and Kinks demonstrate that the target VTM horizon continues throughout the Project.
“This provides additional optionality for Viking to further grow the resource as we continue to
advance this asset and progress to the next stage of the Canegrass Project by incorporating
the recent drill program results into an updated MRE later this year.”
1
ASX Announcement Viking Mines (ASX:VKA) 30 November 2022 – VIKING TO FARM IN TO SUBSTANTIAL BATTERY MINERAL RESOURCE
ASX:VKA
vikingmines.com
15-17 Old Aberdeen Place
West Perth, WA, 6005
P +61 8 6245 0870
F +61 8 9322 5230
contact@vikingmines.com
1
FOLD NOSE TO KINKS SOUTH TARGET AREA DRILLING RESULTS
The recently completed drilling programme included four holes for 530m at the Fold Nose
to Kinks South (FN to KS) exploration target area. Field mapping,2 magnetic geophysics,3 and
rock chip sampling4 identified the target as having high potential to host Vanadium within
the target VTM horizon.
All four drillholes intersected VTM mineralisation, with reportable grades >0.5% V2O5
occurring in the northern two holes which warrant further follow up (Figure 1). The results
from these two holes are presented below:
• VCRC0045: 7m at 0.60% V2O5 (>0.5%) from 63m &
14m at 0.63% V2O5 (>0.8%) from 122m
• VCRC0044: 12m at 0.68% V2O5 (>0.5%) from 60m
Individual high-grade results were returned within the intervals up to a maximum of
1.13% V2O5 in hole VCRC0045 (from 130m to 131m - Figure 2).
Figure 1; Map of Canegrass Project and exploration targets with drilling completed by Viking shown as white triangles.
Intercepts are reported for the Fold Nose to Kinks South target annotated. Results are reported above a 0.5% V2O5 cut-off.
Composite intercepts have been derived for zones>6m width, reporting above minimum cut-off grade and a maximum of 6m
consecutive internal waste zones. Intervals reported are downhole lengths and the true widths are not known.
2
3
4
ASX Announcement Viking Mines (ASX:VKA) 5 January 2023 – VKA Confirms 8km Trend of VTM Outcrop & Commences Farm-In
ASX Announcement Viking Mines (ASX:VKA) 5 April 2023 – Viking Identifies Vanadium Targets from Magnetics Survey
ASX Announcement Viking Mines (ASX:VKA) 2 March 2023 – Viking Receives High-Grade Results up to 1.46% V2O5
ASX:VKA | vikingmines.com
2
Initial wide spaced drilling was planned to test for VTM mineralisation as part of the
Companies 45 hole ~7,500m programme. The area tested is >3km in strike length and
located between the Fold Nose MRE and the Kinks South exploration target. No previous
drilling had been completed in this area and the VTM horizon was previously untested.
The four holes planned were designed to target high magnetic susceptibility zones identified
as part of the magnetic inversion modelling completed at the Project.
The objective of the drilling was to demonstrate that the target horizon continues throughout
the Project area and ascertain the future potential of the target.
Figure 2; Schematic cross section through the Fold Nose to Kinks South target area showing results from holes VCRC0045.
Note the 2 horizons intercepted with thinner zones also present which are below the Company’s standard cut-off reporting rules.
Drillhole Spacing
The drillhole spacing at the FN to KS target area is very wide and ranges from 180m to 800m,
with only one hole has been drilled on each section line. As such there remains a significant
amount of further potential to follow up on these results to identify thick accumulations of
high-grade VTM mineralisation.
Drilling at the Fold Nose, Kinks South and Kinks target areas has demonstrated that thick,
high-grade zones can occur over distances varying from 600m (Kinks) to 1.5km (Kinks
South).5,6
As such, the initial results received for this target area are very encouraging.
5
6
ASX Announcement Viking Mines (ASX:VKA) 24 August 2023 – Viking Hits High-Grade at Kinks With 40m at 0.75% V2O5
ASX Announcement Viking Mines (ASX:VKA) 4 September 2023 – Viking Drills Massive Vanadium Zone with 42m at 0.74% V 2O5
ASX:VKA | vikingmines.com
3
NEXT STEPS
The Company continues to make rapid advancements at the Project. All results from the
~7,500m drilling programme have now been received and reported. On going activities
include:
•
Complete data audit and umpire sampling ahead of commencing MRE update to comply
with all standard JORC requirements for the purpose of MRE reporting.
•
Complete evaluation of downhole density logging data to determine appropriate
densities to apply to domain volumes and block model estimates. It is important to note
that the current MRE utilises an arbitrary density of 3.6 for mineralisation >0.5% V2O5,
whilst the density of massive magnetite regularly exceeds 4.0. This >10% increase will
have a positive effect on the overall estimated tonnages within the MRE.
•
Engage an external contractor to undertake geological modelling and Mineral Resource
Estimation using the results from the recent drilling.
•
Incorporate estimation of Ni, Cu and Co into the Mineral Resource Estimate to assess the
potential of these additional battery minerals at the Project.
END
This announcement has been authorised for release by the Board of Directors.
Julian Woodcock
Managing Director and CEO
Viking Mines Limited
For further information, please contact:
Viking Mines Limited
Sarah Wilson - Company Secretary
+61 8 6245 0870
Forward-Looking Statements
This document may include forward-looking statements. Forward-looking statements include, but are not limited to,
statements concerning Viking Mines Limited’s planned exploration programme and other statements that are not historical
facts. When used in this document, the words such as "could," "plan," "estimate," "expect," "intend," "may”, "potential,"
"should," and similar expressions are forward-looking statements. Although Viking Mines Limited believes that its
expectations reflected in these forward-looking statements are reasonable, such statements involve risks and uncertainties
and no assurance can be given that actual results will be consistent with these forward-looking statements.
Competent Persons Statement – Exploration Results
Information in this release that relates to Exploration Results and exploration target is based on information compiled by
Mr Julian Woodcock, who is a Member and of the Australian Institute of Mining and Metallurgy (MAusIMM(CP) – 305446).
Mr Woodcock is a full-time employee of Viking Mines Ltd. Mr Woodcock has sufficient experience which is relevant to the
style of mineralisation and type of deposit under consideration and to the activity being undertaken to qualify as a
Competent Person as defined in the 2012 Edition of the ‘Australasian Code for Reporting of Exploration Results, Mineral
Resources and Ore Reserves’. Mr Woodcock consents to the disclosure of the information in this report in the form and
context in which it appears.
Competent Persons Statement – Mineral Resources
The information in this report that relates to Mineral Resources is based on, and fairly reflects, information compiled by Mr
Aaron Meakin, a Competent Person who is a Member of the Australasian Institute of Mining and Metallurgy. Mr Meakin is
a consultant to Red Hawk Mining Ltd and Viking Mines Ltd, employed by CSA Global Pty Ltd, independent mining industry
consultants. Mr Meakin has sufficient experience relevant to the style of mineralisation and type of deposit under
consideration and to the activity which he is undertaking to qualify as Competent Person as defined in the 2012 edition of
the Australasian Code for the Reporting of Exploration Results, Mineral Resources, and Ore Reserves (JORC Code). The
Company is not aware of any new information or data that materially affects the information included in the original market
announcements and that all material assumptions and technical parameters underpinning the estimates in the relevant
market announcement continue to apply and have not materially changed. The Company confirms that the form and
context in which the Competent Person’s findings are presented have not been materially modified from the original market
announcements on 30 November 2022.
ASX:VKA | vikingmines.com
4
CANEGRASS BATTERY MINERALS PROJECT
The Canegrass Battery Minerals Project is located in the Murchison region, 620km north-east
of Perth, Western Australia. It is accessed via sealed roads from the nearby township of Mt
Magnet to within 22km of the existing Resources. The Project benefits from a large
undeveloped Inferred Vanadium Resource hosted in vanadiferous titanomagnetite (VTM)
Mineralisation as part of the Windimurra Layered Igneous Complex.
The Project benefits from ~95km2 of exploration tenements with very limited follow up
exploration targeting the growth potential of the vanadium pentoxide (V2O5) Resources in
the +10 years since the Resource was first calculated. Multiple drill ready targets are present
which have the potential to significantly add to the already large Resource base, with high
grade intercepts presenting an opportunity to substantially increase the average grade.
JORC (2012) MINERAL RESOURCE
The Canegrass Mineral Resource has been calculated across two separate areas called the
Fold Nose and Kinks deposits, each with eight and four separate mineralised domains
modelled respectively. The Resource has subsequently been reported above a cut-off grade
of 0.5% V2O5 and above the 210 RL (equivalent to a maximum depth of ~250m) (refer to ASX
Announcement on 30 November 2022).
Canegrass Project Vanadium Mineral Resource estimate, 0.5% V 2O5 cut-off grade, >210m RL (due to the effects of
rounding, the total may not represent the sum of all components).
Fold Nose
JORC
Classification
Inferred
Tonnage
(Mt)
59
V2O5
%
0.66
Kinks
Inferred
20
79
Deposit
TOTAL
30.5
TiO2
%
6.5
Al2O3
%
11.9
P
%
0.006
SiO2
%
22.9
LOI
%
2.9
0.57
27.4
5.5
13.0
0.009
25.9
3.1
0.64
29.7
6.0
12.2
0.007
23.6
3.0
Fe %
VIKING MINES FARM-IN AGREEMENT
Viking, via its wholly owned subsidiary, Viking Critical Minerals Pty Ltd, commenced with a
Farm-In arrangement with Red Hawk Mining Ltd (formerly Flinders Mines Ltd) (ASX:RHK) on
28 November 2022 to acquire an equity interest in the Canegrass Battery Minerals Project.
Through the terms of the Farm-In, Viking can acquire up to 99% of the Project through
completion of 4 stages via a combination of exploration expenditure of $4M and staged
payments totalling $1.25M over a maximum period of 54 months. If Viking complete the
Farm-In to 99% equity interest, Red Hawk Mining may offer to sell to Viking the remaining 1%
of the Project for future production and milestone related payments totalling $850,000. If Red
Hawk Mining do not offer to sell within a prescribed timeframe their right lapses, they must
offer Viking the right (but not the obligation) to buy the remaining 1% for the same terms.
The Project has a legacy 2% Net Smelter Royalty over the project from when Red Hawk Mining
acquired it from Maximus Resources in 2009.
ASX:VKA | vikingmines.com
5
VANADIUM REDOX FLOW BATTERIES – GREEN ENERGY FUTURE
Viking Mines recognise the significant importance of Vanadium in decarbonisation through
the growth of the Vanadium Redox Flow Battery (“VRFB’s”) sector.
VRFB’s are a developing market as an alternate solution to lithium-ion (“Li-ion”) in specific
large energy storage applications. Guidehouse Insights Market Intelligence White Paperi
published in 2Q 2022 forecasts the VRFB sector to grow >900% by 2031 through the
installation of large, fixed storage facilities (Figure 3).
Figure 3; Forecast growth of the VRFB Sector through to 2031 (source – Guidehouse Insightsi)
The reason for this forecast growth is that VRFB’s have unique qualities and advantages over
Li-ion in the large energy storage sector to complement renewable energy sources to store
the energy produced. They are durable, maintain a long lifespan with near unlimited
charge/discharge cycles, have low operating costs, safe operation (no fire risk) and have a
low environmental impact in both manufacturing and recycling. The Vanadium electrolyte
used in these batteries is fully recyclable at the end of the battery’s life.
Importantly, and unlike Li-ion, the battery storage capacity is only limited by the size of the
electrolyte storage tanks. This means that with a VRFB installation, increasing energy storage
capacity is only a matter of adding in additional electrolyte (via the installation of additional
electrolyte storage tanks) without needing to expand the core system components.
Increasing the energy storage directly reduces the levelized cost per kWh over the
installation’s lifetime. This is not an option with Li-ion batteries.
It is for these reasons that VRFB’s are an ideal fit for many storage applications requiring
longer duration discharge and more than 20 years of operation with minimal maintenance.
i) Guidehouse Insights White Paper Vanadium redox Flow Batteries Identifying Market Opportunities and Enablers Published 2Q 2022
https://vanitec.org/images/uploads/Guidehouse_Insights-Vanadium_Redox_Flow_Batteries.pdf
ASX:VKA | vikingmines.com
6
APPENDIX 1 – DRILLHOLE RESULTS TABLES
Intervals >0.5% & >0.8% V2O5 Results
Hole ID
Hole Type
East (m)
MGA94
North (m)
MGA94
RL
End of
Hole (m)
Azi (°)
VCRC0044
RC
638375
6864533
448
108
VCRC0045
RC
638610
6864848
449
150
VCRC0045
RC
Dip (°)
Cut-Off
Depth
From (m)
Length (m)
V 2 O5 %
Fe %
TiO2 %
Cu ppm
Ni ppm
Co ppm
Al2 O3 %
SiO2 %
P ppm
LOI %
142
- 61
0.5% V 2O5
60
12
0.68
29.6
6.3
973
668
147
15.0
23.9
35
1.78
159
- 60
0.5% V 2O5
63
7
0.60
26.6
5.5
936
507
126
16.3
26.3
43
1.78
0.5% V 2O5
122
14
0.63
27.3
5.5
720
679
124
15.5
25.5
51
1.64
Table 1; Drillholes results for composite values based on V2O5 cut-off of 0.5% or 0.8% as noted in the table. 0.8% cut-off intervals overlap the lower 0.5% cut-off and considered to be included within the lower value. Cut-off calculation determined as described in
Appendix 1 - JORC Table 1. For summary, 6m minimum interval above target cut-off grade with a maximum of 6m consecutive internal waste below the target cut-off grade with a minimum composite grade of 0.5% V2O5 and 0.8% V2O5 respectively.
VCRC Drillhole Intervals >600ppm Copper
Hole ID
Hole Type
East (m)
MGA94
North (m)
MGA94
RL
End of
Hole (m)
Azi (°)
Dip (°)
Cut-Off
Depth
From (m)
Length (m)
VCRC0042
RC
638044
6863307
449
140
093
- 70
600ppm Cu
106
14
0.11
10.1
1.1
930
VCRC0044
RC
638375
6864533
448
108
142
- 61
600ppm Cu
56
13
0.63
28.3
5.9
1073
VCRC0045
RC
638610
6864848
449
150
159
- 60
600ppm Cu
63
7
0.60
26.6
5.5
936
VCRC0045
RC
600ppm Cu
122
14
0.63
27.3
5.5
720
V 2 O5 %
Fe %
TiO2 %
Cu ppm
Ni ppm
Co ppm
Al2 O3 %
SiO2 %
P ppm
LOI %
414
80
20.6
40.9
76
4.35
676
145
15.0
25.4
33
2.41
507
126
16.3
26.3
43
1.78
679
124
15.5
25.5
51
1.64
Table 2; Drillhole results for composite values for VCRC drillholes based on Cu cut-off of 600ppm (0.06%) as noted in the table. These intervals overlap those that are reported in Error! Reference source not found. above for V2O5. Cut-off calculation
determined as described in Appendix 1 - JORC Table 1. For summary, 6m minimum interval above target cut-off grade with a maximum of 6m consecutive internal waste below the target cut-off grade with a minimum composite grade of 600ppm.
ASX:VKA | vikingmines.com
7
APPENDIX 2 – JORC CODE, 2012 EDITION – TABLE 1
JORC Table 1, Section 1 – Sampling Techniques and Data
Criteria
Sampling
techniques
Drilling
techniques
JORC Code explanation
RC drilling collected samples during the drilling process using industry standard techniques including
face sampling drill bit and cone splitter. Chip samples are collected from the drill cuttings and sieved
and put into chip trays for geological logging.
Include reference to measures taken to ensure sample representivity and the
appropriate calibration of any measurement tools or systems used.
Cone splitter is an industry standard sampling device which sup-splits the metre drilled into
representative samples. QAQC measures including the use of duplicate samples checks the suitability
of this method to retain representative samples. Based on a review of the sampling data, samples are
representative of the interval drilled.
Aspects of the determination of mineralisation that are Material to the Public
Report. In cases where ‘industry standard’ work has been done this would be
relatively simple (e.g. ‘reverse circulation drilling was used to obtain 1 m samples
from which 3 kg was pulverised to produce a 30 g charge for fire assay’). In other
cases more explanation may be required, such as where there is coarse gold that
has inherent sampling problems. Unusual commodities or mineralisation types (e.g.
submarine nodules) may warrant disclosure of detailed information
Drill type (e.g. core, reverse circulation, open-hole hammer, rotary air blast, auger,
Bangka, sonic, etc.) and details (e.g. core diameter, triple or standard tube, depth of
diamond tails, face-sampling bit or other type, whether core is oriented and if so, by
what method, etc.).
Method of recording and assessing core and chip sample recoveries and results
assessed.
Drill sample
recovery
Logging
Commentary
Nature and quality of sampling (e.g. cut channels, random chips, or specific
specialised industry standard measurement tools appropriate to the minerals under
investigation, such as downhole gamma sondes, or handheld XRF instruments,
etc.). These examples should not be taken as limiting the broad meaning of
sampling.
Measures taken to maximise sample recovery and ensure representative nature of
the samples.
Whether a relationship exists between sample recovery and grade and whether
sample bias may have occurred due to preferential loss/gain of fine/coarse
material.
Whether core and chip samples have been geologically and geotechnically logged
to a level of detail to support appropriate Mineral Resource estimation, mining
studies and metallurgical studies.
Whether logging is qualitative or quantitative in nature. Core (or costean, channel,
etc.) photography.
The total length and percentage of the relevant intersections logged.
If core, whether cut or sawn and whether quarter, half or all core taken.
ASX:VKA | vikingmines.com
Reverse circulation drilling was used to obtain 1m samples which were collected from the cone splitter.
Samples have been composited in some cases to either 2 or 4m composites by scooping from the calico
bag collected from the cone splitter at the rig. Samples have been dispatched to ALS laboratories in
Perth for analysis by XRF fused bead analysis. If sample weight exceed 3kg they are crushed and split
using a rotary splitter at the laboratory to produce a 3kg sample. The samples are then pulverized to
85% <75um to produce a sample for analysis XRF methods.
Reverse circulation drilling using a 5 ½ inch bit and a face sampling hammer.
Recovery of sample is recorded by the field assistant when sampling and noted as either Good, Fair or
Poor. Of the 418 samples collected at Fold Nose to Kinks South target area, all samples reported good
recovery, 0 fair recovery and 0 with poor recovery.
Drilling recovery is assessed by observing sample size. Samples are collected from the cyclone using a
cone splitter and monitored for size to determine that they are representative.
No relationship has been identified between sample recovery and grade. This is reflected by all samples
collected having a good recovery. Further, due to the nature of the mineralisation under investigation
and the relatively high values obtained, the impact of fines is not considered to be of significance.
All chip samples have been geologically logged to a sufficient level to support any future mineral
resource estimation, mining studies and metallurgical studies. All chip samples are retained at the
Company offices and are available for further inspection when undertaking this future work.
Logging of samples is qualitative in nature. Chip photos are taken of the chip trays. All the drill spoils at
the drill site are photographed to retain a record of the colour variation within the hole.
All metres drilled have been geologically logged.
Not applicable.
8
JORC Code explanation
Criteria
If non-core, whether riffled, tube sampled, rotary split, etc. and whether sampled
wet or dry.
For all sample types, the nature, quality and appropriateness of the sample
preparation technique.
Subsampling
techniques and
sample
preparation
Quality control procedures adopted for all subsampling stages to maximise
representivity of samples.
Measures taken to ensure that the sampling is representative of the in-situ material
collected, including for instance results for field duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain size of the material being
sampled.
The nature, quality and appropriateness of the assaying and laboratory procedures
used and whether the technique is considered partial or total.
Quality of assay
data and
laboratory tests
For geophysical tools, spectrometers, handheld XRF instruments, etc., the
parameters used in determining the analysis including instrument make and model,
reading times, calibrations factors applied and their derivation, etc.
ASX:VKA | vikingmines.com
Commentary
Samples were collected from the cyclone using a cone splitter for each metre drilled in to 2 calico bags.
When composite samples were collected, a scoop is used to collect equal amounts from each metre
interval used to make the composite sample. Dry samples are collected.
The sample preparation of the RC samples follows industry best practice, involving oven drying,
pulverising, to produce a homogenous sub sample for analysis. All samples were pulverised to a nominal
85% passing 75-micron sizing and sub sampled for assaying and LOI determination tests. The sample
preparation techniques are of industry standard and are appropriate for the sample types and proposed
assaying methods.
Other than field duplicate sampling, the laboratory conducts duplicate analysis on pulp samples to
confirm repeatability of the pulverised material. A batch of umpire analysis are being selected and
scheduled for analysis to provide an additional check on repeatability of results and determine
appropriateness of the subsampling and homogenisation process.
Drilling was conducted using a 5 ½ inch hammer to collect 1m samples. As the style of mineralisation is
massive to disseminated with results for V2O5 being measured in %, the samples collected are deemed
representative. To monitor this, duplicate samples are collected from the cyclone at a frequency rate of
approximately 1 per 40 samples collected. Of the 418 samples collected, a further 10 duplicate samples
were taken (2.4%). Samples are selected from expected mineralised intervals to provide meaningful
data to compare the original vs the duplicate. Duplicate samples show a good correlation against the
original sample collected indicating that sampling is representative of the in-situ material collected.
Plotting results on a chart gives a regression line with an R2 value of 0.9809 for V2O5.
The nature and style of the mineralisation is relatively homogenous and as such the sample sizes
collected are appropriate to the grain size of the material being sampled.
Sample collected by Viking and submitted to ALS geochemistry for analysis were assayed for the full
iron ore suite by XRF (24 elements) (lab code ME-XRF21n) and for total LOI by thermo-gravimetric
technique (ME-GRA05). The method used is designed to measure the total amount of each element in
the sample. A prepared sample (0.66g) is fused with a 12:22 lithium tetraborate – lithium metaborate
flux which also includes an oxidizing agent (Lithium Nitrate), and then poured into a platinum mould.
The resultant disk is in turn analysed by XRF spectrometry for major rock forming elements and
selected trace element concentrations. The method is deemed suitable and appropriate for the style of
mineralisation.
Field tools were used to assist in identification of the VTM horizon for sampling. A KT-10 magnetic
susceptibility meter has been used which measures the magnetic susceptibility of the sample. Unit
specifications are:
•
Circular coil design
•
Sensitivity: 10-6 SI units
•
Measurement range:
0.001 x 10-3 to 1999.99 x 10-3 SI units
No calibration factors are applied to the data. The duration for the measurement sequence is 7
seconds.
9
JORC Code explanation
Criteria
Nature of quality control procedures adopted (e.g. standards, blanks, duplicates,
external laboratory checks) and whether acceptable levels of accuracy (i.e. lack of
bias) and precision have been established.
The verification of significant intersections by either independent or alternative
company personnel.
The use of twinned holes.
Verification of
sampling and
assaying
Documentation of primary data, data entry procedures, data verification, data
storage (physical and electronic) protocols.
Discuss any adjustment to assay data.
Accuracy and quality of surveys used to locate drillholes (collar and downhole
surveys), trenches, mine workings and other locations used in Mineral Resource
estimation.
Location of data
points
Specification of the grid system used.
Quality and adequacy of topographic control.
Data spacing for reporting of Exploration Results.
Data spacing
and distribution
Whether the data spacing, and distribution is sufficient to establish the degree of
geological and grade continuity appropriate for the Mineral Resource and Ore
Reserve estimation procedure(s) and classifications applied.
Whether sample compositing has been applied.
ASX:VKA | vikingmines.com
Commentary
A comprehensive QAQC programme involving the insertion of standards (certified reference materials
– CRM’s), blanks and duplicates has been implemented. Viking inserts standards at a frequency of 1:25,
blanks 1:40 and duplicates 1:40. 3 x CRM’s have been used by the company which were sourced from
GeoStats and are certified for 21 elements (including Vanadium) and LOI. Results from the laboratory
for the CRM’s are plotted against the CRM values for the mean and 1,2, and 3 standard deviations from
the mean. 2 of the 3 standards all performed within expected levels with 1 standard demonstrating
good precision and a minor positive bias for accuracy. Further check assaying on 10 standards has been
completed and confirmed that the minor positive bias is repeatable, indicating that the standard is
reporting positive and is inherent to the standard samples being analysed. The magnitude of the bias
has been reviewed and is deemed insignificant with respect the values being reported (~0.02% V2O5
positive bias).
QAQC results including CRMs, duplicate samples, repeat analysis and blanks for both Viking sample
submissions and internal lab checks show no material issues for the recent assaying programmes.
No independent verification of significant intersections have been completed. An independent
consultant is being engaged to audit the DH database ahead of undertaking a MRE on the project in the
Sep/Dec quarter 2023.
No twinned holes have been completed.
Data is collected in the field into digital devices and loaded into the company database by the
companies database manager. All records are collected and stored on the companies server and cloudbased storage systems (SharePoint). Physical paper copies are also created as a part of the data
collection process and are scanned and saved to SharePoint.